Patient Monitor Accessories

MIV

[vc_row][vc_column width=”1/2″][vc_column_text]

Key Features

 

Immediate results
Small, portable capnograph
Designed to fit easily onto a breathing circuit
Rugged design for reliable operation in challenging environments
Clear, continuous capnograph of carbon dioxide values
Simple, easy-to-use interface for quick set-up

[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_single_image image=”1479″ img_size=”medium” alignment=”center” title=”What Does Complete the Operating Room?”][/vc_column][/vc_row][vc_row][vc_column color=”#000000″][nz_tabs][nz_tab title=”Description”]During surgery under general anesthesia, the anesthesia will adjust the amount of anesthesia drugs to ensure that the patient remains unconscious. This adjustment is made according to clinical signs, such as the patient’s heart rate or blood pressure, or end-tidal anesthesia gas (ETAG) for anesthesia that is given as a gas, which is a measure of the amount of remaining gas after the patient breathes out. However, using these methods alone may increase the chance that the patient is given too little or too much anesthesia. Intraoperative awareness, a distressing event in which a patient may become conscious enough to recall events during surgery, is very rare and may be caused by too little anesthesia. Too much anesthesia may lead to a longer time needed to reach full recovery. Bispectral index (BIS) is a measurement scale based on the electrical activity in the brain, and by using a monitor of brain activity during anesthesia, the anesthesia may use this scale to inform the amount of anesthesia to give to the patient.  You can measure to BIS factor by this device easily .[/nz_tab][nz_tab title=”Measurement “]

Index of Consciousness
SQI, ESR, EMG and BIS Measurement

[/nz_tab][nz_tab title=”Technical Highlightsa”]

Compliance with Europe Standards
Offered Accessories and Peripherals by Vistamedikal Medical
Equipment Industries
Easy Installation and Utilization
Bluetooth Interaction with Vistamedikal Patient Monitors
Waveform Display on Patient Monitor and Saving as Trend
Graphical Low Consumption LCD
Minimum 6 Hours Operation Time Using External Rechargeable
Battery

[/nz_tab][/nz_tabs][/vc_column][/vc_row][vc_row][vc_column][vc_column_text]

Last sentence:

We recommend you to visit other special categorize in our site by following link:

smart hospital solution

modular operating room equipment

telemedicine equipment

Tele monitoring equipment

multi parameter vital sign monitor

electric surgical suction

operating room management system equipment

Spinal implant equipment

Patient entertainment system equipment

building management system for hospital equipment

[/vc_column_text][/vc_column][/vc_row]

Leave a Reply

Your email address will not be published. Required fields are marked *